BXDSY - CYTOLOGY FIXATION

Product Identification

Product ID:CYTOLOGY FIXATION
MSDS Date:09/01/1992
FSC:6810
NIIN:00N035284
MSDS Number: BXDSY

Responsible Party
SURGIPATH MEDICAL INDUSTRIES INC
5205 ROUTE 12
RICHMOND, IL 60071
US

Emergency Phone: 800-424-9300 (CHEMTREC)

Info Phone: 815-678-2000

Preparer: KEN URBAN

Cage: 0U703

Contractor
SURGIPATH MEDICAL INDUSTRIES
RICHMOND, IL 60071 US

Telephone: 800-225-8867;815-678-2000

Cage: 0U703

Ingredients

ETHYL ALCOHOL; (ETHANOL, 95%)

CAS: 64-17-5

RTECS: KQ6300000

OSHA PEL 1000 PPM

ACGIH TLV: 1000 PPM


POLYETHYLENE GLYCOL

CAS: 25322-68-3

RTECS: TQ3500000

OSHA PEL N/K

ACGIH TLV: N/K


PHENOTHIAZIN-5-IUM, 3-AMINO-7-(DIMETHYLAMINO)-2- METHYL-,

CAS: 92-31-9

RTECS: SP5670000

OSHA PEL N/K

ACGIH TLV: N/K


METHYL ALCOHOL; (METHANOL (DENATURANT)) (SARA 313)

CAS: 67-56-1

RTECS: PC1400000

Fraction By Weight: <5%

OSHA PEL 200 PPM, S

ACGIH TLV: 200 PPM; 250 STEL, S

EPA Report Quantity: 5000 LBS

DOT Report Quantity: 5000 LBS


ISOPROPYL ALCOHOL; (ISOPROPYL ALCOHOL (DENATURANT)) (SARA

CAS: 67-63-0

RTECS: NT8050000

Fraction By Weight: <10%

OSHA PEL 400 PPM

ACGIH TLV: 400 PPM; 500 STEL

Hazards

LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:YES Skin:YES Ingestion:YES
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:ACUTE: MAY CAUSE IRRITATION TO EYES,
NOSE, THROAT AND HEADACHE. CHRONIC: LOSS OF APPETITE, INABILITY TO
CONCENTRATE.
Explanation of Carcinogenicity:NOT RELEVANT
Effects of Overexposure:SEE HEALTH HAZARDS.
Medical Cond Aggravated by Exposure:UNKNOWN.

First Aid

First Aid:INHAL: REMOVE TO FRESH AIR AND PROVIDE OXYGEN IF NECESSARY.
GET MEDICAL ATTENTION. EYES: FLUSH WITH WATER FOR AT LEAST 15
MINUTES. GET MEDICAL ATTENTION. SKIN: WASH THOROUGHLY WITH SOAP AND
WATER. RIN SE. INGEST: INDUCE VOMITING. GIVE TWO GLASSES OF WATER.
GET MEDICAL ATTENTION.

Fire Fighting

Flash Point:59.0F,15.0C
Lower Limits:3.3%
Upper Limits:19.0%
Extinguishing Media:ALCOHOL FOAM, CARBON DIOXIDE, DRY CHEMICALS.
Fire Fighting Procedures:USE NIOSH/MSHA APPROVED SCBA AND FULL
PROTECTIVE EQUIPMENT . COOL EXPOSED CONTAINERS WITH WATER.
Unusual Fire/Explosion Hazard:NONE. HANDLE AS A FLAMMABLE LIQUID.

Accidental Release

Spill Release Procedures:ELIMINATE ALL IGNITION SOURCES. WEAR
NIOSH/MSHA APPROVED RESPIRATOR. DIKE AND REMOVE LIQUID IN APPROVED
SALVAGE CONTAINER.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.

Handling

Handling and Storage Precautions:STORE AT ROOM TEMPERATURE (70F) AWAY
FROM HEAT, SPARKS, OPEN FLAMES.
Other Precautions:NONE. HANDLE AS FLAMMABLE LIQUID.

Exposure Controls

Respiratory Protection:USE NIOSH/MSHA APPROVED BREATHING APPARATUS TO
PREVENT OVEREXPOSURE IF VAPOR LEVELS EXCEED TLV.
Ventilation:LOCAL EXHAUST RECOMMENDED. MECHANICAL (GENERAL) IN CONFINED
AREAS. SPECIAL NOT NORMALLY REQUIRED.
Protective Gloves:PLASTIC OR RUBBER.
Eye Protection:ANSI APPRVD CHEM WORKERS GOGGLES .
Other Protective Equipment:EYE BATH, SAFETY SHOWER.
Work Hygienic Practices:NONE SPECIFIED BY MANUFACTURER.
Supplemental Safety and Health
NONE SPECIFIED BY MANUFACTURER.

Chemical Properties

Boiling Pt:B.P. Text:>169F,>76C
Vapor Pres:44 @ 68F
Vapor Density:1.5
Evaporation Rate & Reference:1.4 (BUTYL ACETATE=1)
Solubility in Water:COMPLETE
Appearance and Odor:CLEAR, COLORLESS LIQUID; ALCOHOL ODOR.
Percent Volatiles by Volume:100

Stability

Stability Indicator/Materials to Avoid:YES
STRONG OXIDIZING AGENTS.
Stability Condition to Avoid:HEAT, SPARKS, OPEN FLAMES.
Hazardous Decomposition Products:CARBON MONOXIDE FROM INCOMPLETE
COMBUSTION.

Disposal

Waste Disposal Methods:REMOVE TO APPROVED HAZARDOUS WASTE FACILITY IN
ACCORDANCE WITH LOCAL, STATE AND FEDERAL REGULATIONS.

Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.